Ingenio® Electroporation Kits and Solutions
- 良好的電穿孔效率:可有效地將 DNA, RNA, siRNA, miRNA 等核酸樣本送入真核細胞中,即使是難以轉染的幹細胞或初代細胞皆能擁有高轉染效率!
- 低細胞毒性:相較於他牌產品,Ingenio® 毒性更低,可保有更高的細胞存活率。
- 適用於各種電穿孔設備機型:包含 Lonza-Amaxa®, Bio-Rad®, Harvard BTX® 等。
- 價格更便宜:使用 Ingenio® 不僅可提供與 Amaxa® Nucleofector® Kits 相比擬的運送效率,還可讓您省下更多實驗經費。
- 產品選擇彈性多元:具有完整試劑組合以及獨立試劑、耗材配件……多種規格款式可選。
歡迎與我們聯繫索取更多 Ingenio® 產品資訊與文獻。
想要讓您的電穿孔實驗更高效、直覺、便利?
別錯過專為 Ingenio® 電穿孔試劑打造的【Ingenio® EZporator® 電穿孔儀】
產品效能
Fig. 1 | Ingenio® Outperforms Other Electroporation Solutions in Efficiency and Viability. Cells were electroporated in parallel with an EGFP reporter vector using either Ingenio® Electroporation Solution, PBS or the Gene Pulser Electroporation Buffer (Bio-Rad®) on the Gene Pulser Xcell™ Eukaryotic System. (A) EGFP expressing cells were identified 24 hours post-electroporation by flow cytometry and presented as a percentage of the live cell population. (B) Cells were assayed for viability by propidium iodide staining and flow cytometry analysis. Experiments were performed in triplicate on three separate days and the data averaged.
Fig. 2 | Ingenio® Solution Provides Comparable Efficiency on Amaxa® Nucleofector® Device. Cells were electroporated in parallel with an EGFP reporter vector using a Nucleofector® II Device (Amaxa®) and either the Ingenio® Electroporation Solution or the Nucleofector® Kit V (Amaxa®) according to Amaxa®’s recommended protocol for each cell line [HL-60 (T-019), Jurkat E6-1(X-001), K-562 (T-016), THP-1 (V-001), SK-N-MC (A-023), and MCF-7 (P020)]. EGFP expressing cells were identified 24 hours post-electroporation by flow cytometry and presented as a percentage of the live cell population.
Fig. 3 | Using Standard Electroporators, Ingenio® Provides High Efficiency Electroporation of Hard to Transfect Cell Lines. Cells were electroporated with an EGFP reporter vector using the Ingenio® Electroporation Solution and a Gene Pulser Xcell™ Eukaryotic System. EGFP expressing cells were identified 24 hours post-electroporation by flow cytometry and presented as a percentage of the live cell population.
Fig. 4 | CRISPR RNP Delivery with Ingenio® Electroporation Solution. K562 and Jurkat cells were electroporated with a Cas9 protein/gRNA, ribonucleoprotein (RNP) complex, composed of 750 nM Cas9 protein (EnGen® Cas9 NLS, NEB) and 1500 nM pre-complexed two-part gRNA (IDT) targeting PPIB using the Ingenio® Electroporation Solution and a Gene Pulser Xcell™ Eukaryotic System. Exponential pulse conditions of 130V, 950 µF for K562 and 150V, 950 µF for Jurkat cells were applied to triplicate 0.2 cm cuvettes, 100 µl volume, 10 x 10⁶ cells/ml +/- RNP complex. A T7E1 mismatch assay was used to measure cleavage efficiency at 48 hours post-transfection. Non-specific bands (NSP) were observed in the negative control of both cell lines. Cleavage efficiency was calculated based on the ratio of cleaved band intensities to the sum of cleaved and uncleaved band intensities minus the average signal of the non-specific band(s) in negative control lanes.
Fig. 5 | High Efficiency Plasmid DNA Electroporation of Human Induced Pluripotent Stem (iPS) Cells Using Ingenio®. The Ingenio® Electroporation Kit was used to transfect 2 x 10⁶ iPS cells on the Amaxa® Nucleofector® II Device. Cells were electroporated with 8 µg ZsGreen expressing plasmid (Clontech) in 100 µl and plated in 6-well plates at 0.33 x 10⁶ cells/well. Cells were visualized 24 hours post-transfection and imaged under 4X objective with an Olympus IX71® Inverted Microscope. Images are (A) phase contrast, and (B) green fluorescence. Cells were also assayed 24 hours post-transfection on an Accuri® Cytometer. The histogram (C) shows unelectroporated cells (black line) compared to cells electroporated with plasmid using the Ingenio® Electroporation Kit (green line).
訂購資訊
Product Name | Pack Size | Cat. No. |
---|---|---|
Ingenio® Electroporation Kit for the EZporator® Electroporation System and Lonza-Amaxa® Nucleofector® II/2b devices (0.2 cm cuvettes and cell droppers) | 25 rxn | MR-MIR50112 |
50 rxn | MR-MIR50115 | |
100 rxn | MR-MIR50118 | |
Ingenio® Electroporation Kits for the EZporator® Electroporation System and all conventional electroporators such as Bio-Rad® and Harvard-BTX® (0.4 cm cuvettes and cell droppers) | 25 rxn | MR-MIR50113 |
50 rxn | MR-MIR50116 | |
100 rxn | MR-MIR50119 | |
Ingenio® Electroporation Solution | 25 rxn | MR-MIR50111 |
50 rxn | MR-MIR50114 | |
100 rxn | MR-MIR50117 | |
Ingenio® Cell Droppers | 50 ea | MR-MIR50125 |
Ingenio® Cuvettes for the EZporator® Electroporation System and Lonza-Amaxa® Nucleofector® II/2b devices (0.2 cm cuvettes) | 50 ea | MR-MIR50121 |
Ingenio® Cuvettes for the EZporator® Electroporation System and all conventional electroporators such as Bio-Rad® and Harvard-BTX® (0.4 cm cuvettes) | 50 ea | MR-MIR50123 |